600 Volt UL Type MC, XLP XHHW-2 Insulation
Specifications:
- Impervious Continuously Welded Armor – Control Cable
- 600 Volt UL Type MC, CT Use, 90°C
- XLP XHHW-2 Insulation
- Aluminum Armor
- Copper Conductors
Application:
For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded corrugated armor cable is recommended as an economical alternative to wire in conduit systems.
Conductors:
Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).
Insulation:
Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.
Armor:
Impervious continuously welded and corrugated aluminum.
Jacket:
Black sunlight-resistant PVC
Flame Tests:
- UL 1581 70,000 BTU/hr flame test
- ICEA 70,000 BTU/hr and 210,000 BTU/hr flame test
- IEEE 383 70,000 BTU/hr flame test
Color Code:
ICEA Method 1, Table E-2
Additional Standards:
- UL listed, NEC Type MC, UL Standard 1569
- UL listed Type CWCMC to IEEE 45/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.
- Meets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test
Connectors:
- Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components
- Rain Tight: 416MC series – all nickel-plated brass
Size AWG | No. of Conductors | Net Weight Lbs./Mft | Catalog Number | Action |
14 | 2 | 135 | HW306 01402 | Request A Quote |
14 | 3 | 155 | HW306 01403 | Request A Quote |
14 | 4 | 185 | HW306 01404 | Request A Quote |
14 | 5 | 210 | HW306 01405 | Request A Quote |
14 | 7 | 250 | HW306 01407 | Request A Quote |
14 | 9 | 320 | HW306 01409 | Request A Quote |
14 | 12 | 380 | HW306 01412 | Request A Quote |
14 | 19 | 530 | HW306 01419 | Request A Quote |
14 | 25 | 685 | HW306 01425 | Request A Quote |
14 | 37 | 935 | HW306 01437 | Request A Quote |
12 | 2 | 165 | HW306 01202 | Request A Quote |
12 | 3 | 190 | HW306 01203 | Request A Quote |
12 | 4 | 230 | HW306 01204 | Request A Quote |
12 | 5 | 265 | HW306 01205 | Request A Quote |
12 | 7 | 330 | HW306 01207 | Request A Quote |
12 | 9 | 410 | HW306 01209 | Request A Quote |
12 | 12 | 500 | HW306 01212 | Request A Quote |
12 | 19 | 715 | HW306 01219 | Request A Quote |
10 | 2 | 205 | HW306 01002 | Request A Quote |
10 | 3 | 240 | HW306 01003 | Request A Quote |
10 | 4 | 300 | HW306 01004 | Request A Quote |
10 | 5 | 345 | HW306 01005 | Request A Quote |
10 | 7 | 440 | HW306 01007 | Request A Quote |
10 | 9 | 550 | HW306 01009 | Request A Quote |
10 | 12 | 690 | HW306 01012 | Request A Quote |