Prysmian’s Low Voltage AIRGUARD™ Instrumenation
Cables are primarily designed for applications in the harsh
environments found in the heavy industrial and offshore
markets. Its rugged polymeric Airbag™ armor and chemical
barrier protection package makes it the ideal cable choice
for tough harsh environmental conditions. AIRGUARD™
provides the solution to the deficiencies often encountered
with MC-HL cables including armor breakage encountered
during installation and in applications requiring recurring
bending after installation, as well as poor performance
in areas of high vibration (e.g. motor connections). It also
provides a safer and lower installed cost alternative to
MC-HL cables due to faster, “No Knife/ No Saw” cable
preparation, and substantially reduced cost of cable glands.
Conductor: Class B stranded bare, soft drawn copper circuit conductors
Insulation: Heat and moisture resistant cross-linked polyethylene (XLPE) meeting the requirements of UL-44 for Type XHHW-2 conductors.
Fillers: Flame resistant non-hygroscopic fillers (as needed)
Drain Wires: Class B stranded bare, soft drawn tinned copper drain wire.
Assembly: An aluminum/ polyester tape with drain wire,100% coverage, is applied over the twisted pairs or triads and the cabled core. Single pair or traid constructions have only the overall shield and drain wire.
Polymeric Armor/Enviromental Barrier: Foamed polymeric AIRBAG™ layer affords superior mechanical & environmental protection of the cable core
Outer Sheath: Heat, moisture, hydrocarbon, and sunlight resistant thermoplastic
Installation
• In Cable Tray Conduit
• Direct Buried Underground Duct
• Isolated in Air Wet Locations
• Dry Locations Industrial
• With Messenger
Specifications:
• ASTM B3 & ASTM B8 Class B Soft Drawn ConcentricLay Stranded Bare Copper Conductors
• ICEA S-82-552 (NEMA WC55) Instrumentation Cable Rating
• UL 44 (XHHW-2) 600V XHHW-2 Multiple Conductors Direct Buried Sunlight Resistant Oil Resistant
• iEEE 1202/FT-4 Flame Retardant
• UL 1277 NEC Article 336.10(7) TC-ER Exposed Run Rating
• UL 2225 NEC Article 501.10(A)(2)(3) TC-ER-HL Class I Division 1 Hazardous Locations
• NEC Article 505.15(B)(1)(i) TC-ER-HL Class I Zone 1 Hazardous Locations
• CSA 22.2 No. 03 -40°C / -35°C Cold Bend/Cold Impact
Technical Specifications | |
Number and Circuit Conductor Size |
4/TR #16 AWG |
Insulation Thickness (Mils) |
30 |
Conductor Diameter (Inches) |
0.059 |
Nominal Overall Insulation OD (Inches) |
0.123 |
Nominal Overall Cable OD (Inches) |
1.050 |
Nominal Cable Weight (lbs/Mft) |
540 |
Minimum Bending Radius (Inches) |
12.6 |
Ampacity (Amps) (‡90°c) |
9.0 |
Gland, Explosion Proof, Class 1 Division 1,Barrier Type |
424BT15 |
Prysmian and Draka Cable Part Number |
394059 |