Stranded tin-coated copper conductor, cross-linked polyethylene insulation. Telephone Identification Code by Method
3. Two conductors cabled to form a pair. 42 pairs cabled together consecutively with fillers, binder tape, braided shield
of tin-coated copper, separator tape, cross-linked polyolefin jacket, surface marking.
LS2UWA: Same, aluminum armor, paint. LS2UWS: Same, double overall shield.
technical specification: | |
conductor size: awg mcm | 26 |
number of conductor in cable | 84 |
cable type designation | LS2UWS-42 |
area of each conductor(mcm) | 0.278 |
cable overall diameter max.(inch) | .840 |
cable weight perft. appox.(lbs) | .665 |
radius of bend min.(inch) | 10.0 |
cdr id | TEL-3 |
rated voltage max.(rms) | — |
nsn | 6145-01-202-7002 |
seacoast and military Part Number | M24643/57-03UD |