Sizes 3-23: Stranded uncoated copper conductor, extruded silicone rubber insulation, glass braid, braid covering.
Standard Identification Code by Method 2, two conductors cabled with fillers, binder or combination binder and
barrier. LSDSGU: cross-linked polyolefin jacket, LSDSGA: cross-linked polyolefin jacket, braided aluminum armor,
paint. Sizes 50-400: Same except silicone rubber-glass tape insulation, no glass braid or braid covering. Letter
Identification Code by Method 5 binder. LSDSGS: same as LSDSGU except double overall shield.
technical specification: | |
conductor size: awg or mcm | 7 |
number of conductors in cable | 2 |
cable type designation | LSDSGU-23 |
area of each conductor(mcm) | 20.820 |
cable** overall diameter max.(inch) | .781 |
cable weight per ft. appox.(lbs) | .363 |
radius of bend min.(inch) | 5.0 |
cdr id | STD-1 |
rated voltage max.(rms) | 1000 |
ampacity, each conductor(amps,max) dc or 60 hz (40°c ambient) | 78 |
ampacity, each conductor(amps,max) dc or 60 hz(50°c ambient) | 72 |
ampacity, each conductor(amps,max) 400 hz(40°c ambient) | 78 |
ampacity, each conductor(amps,max) 400 hz(50°c ambient) | 72 |
nsn | 6145-01-202-2798 |
seacoast and military part number | MIL-C-24643/15-05UN |