Belden 6500PE Cable 22 AWG 2 Conductors Security and Commercial Audio Plenum CMP Stranded Flamarrest Jacket Cable
Description:
• Security & Commercial Audio Cable, Plenum-CMP, 2-22 AWG stranded tinned copper pairs with Flamarrest® insulation, Individually Beldfoil® shielded and Flamarrest® jacket with ripcord
Insulation:
• Trade Name: Flamarrest®
• Material: LS PVC – Low Smoke Polyvinyl Chloride
• Wall Thickness (mm): 0.241
Outer Shield Drain Wire AWG:
• AWG: 24
• Stranding: 7×32
• Material: TC – Tinned Copper
Outer Jacket:
• Trade Name: Flamarrest®
• Material: LS PVC – Low Smoke Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.381
• Outer Jacket Ripcord: Yes
Overall Cabling Lay Length and Direction:
• Length (mm): 63.49975
• Twist (twist/m): 15.7488
Usage (Overall):
Applications:
• Intercom/PA Systems and Sound/Audio Systems.
Mechanical Charactertistics (Overall):
• Operating Temperature Range: 0°C To +75°C
• UL Tempeature Rating: 75°C
• Bulk Cable Weight: 16.370 Kg/Km
• Max. Recommended Pulling Tension: 106.757 N
• Min. Bend Radius/Minor Axis: 33.020 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMP
• NEC Articles: 800
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 03/23/2010
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Inductance (μH/m): 0.591
• Nom. Capacitance Conductor to Conductor (pF/m): 147.645
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/m): 265.761
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 53.8084
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 54.957
• Max. Operating Voltage – UL: 300 V RMS
• Max. Recommended Current: 2.8 Amps/Conductor @ 25°C
Flame Test:
• UL Flame Test: NFPA 262
• C(UL) Flame Test: FT6
Plenum/Non-Plenum:
• Plenum (Y/N): Yes
technical specification: | |
awg | 22 |
# conductors | 2 |
stranding | 7×30 |
no. of conductors | 2 |
conductor material | bare copper |
dia. (mm) | – |
outer shield – type | tape |
outer shield – material | aluminum foil-polyester tape w/shorting fold |
overall cable- nominal dia, (mm.) | 3.302 |
belden cable part number | 6500PE |