Belden S1328NH Cable 18 AWG 5 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7×26 LSZH Jacket Cable
Description:
• 18 AWG stranded (7×26) tinned copper conductors, polyolefin insulation, individual & overall Beldfoil® shield (100% coverage), tinned copper drain wire, LSZH jacket.
Insulation:
• Material: PO – Polyolefin
Inner Shield:
• Type: Tape
• Inner Shield Material: Aluminum Foil-Polyester Tape
Inner Shield Drain Wire AWG:
• AWG: 20
• Stranding: 7×28
• Conductor Material: TC – Tinned Copper
Outer Shield Drain Wire AWG:
• AWG: 18
• Stranding: 7×26
• Conductor Material: TC – Tinned Copper
Outer Jacket:
• Material: LSZH – Low Smoke Zero Halogen
• Outer Jacket Ripcord: Yes
Mechanical Characteristics (Overall):
• Operating Temperature Range: -30°C To +90°C
• UL Temperature Rating: 90°C
• Max. Recommended Pulling Tension: 309 lbs.
• Min. Bend Radius/Minor Axis: 5.500 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CM, ITC, PLTC
• CEC/C(UL) Specification: CM
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 11/19/2007
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Unaveraged Impedance (Ohm): 100.000
• Nom. Inductance (μH/ft): 0.190
• Nom. Capacitance Conductor to Shield (pF/ft): 45.000
• Nom. Mutual Capacitance (pF/ft): 24.000
• Maximum Capacitance Unbalance (pF/ft): 1.200
• Nominal Velocity of Propagation: VP (%): 66.000
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 5.860
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 4.900
• Ind. Pair Nominal Shield DC Resistance @ 20 Deg C: 7.500 Ohm/1000 ft
• Max. Operating Voltage – UL: 300 V RMS
• Max. Recommended Current: 5.2 Amps/Conductor
Flame Test:
• UL Flame Test: UL1685 Vertical Tray Flame Test
• IEC Flame Test: IEC 332-3 Category C Bunched Cables
Suitability:
• Suitability – Indoor: Yes
• Suitability – Outdoor: Yes
• Sunlight Resistance: Yes
• Oil Resistance: Yes
Plenum/Non-Plenum:
• Plenum(Y/N): No
technical specification: | |
awg | 18 |
# pairs | 5 |
stranding | 7×26 |
no. of conductors | 10 |
conductor material | tinned copper |
diameter (in.) | 0.048 |
outer shield – type | tape |
outer shield – material | aluminum foil-polyester tape |
overall cable – nominal diameter (in.) | 0.550 |
belden cable part number | S1328NH |