Technical Data:
• Special PUR drag chain cable, extreme flexibility acc. to UL/CSA AWM I/II A/B Style 21223
Temperature Range
• Flexing -5°C to +80°C
• Fixed installation -40°C to +80°C
Nominal Voltage
• VDE U0/U 300/500 V
UL/CSA 1000 V
Test Voltage
• 4000 V
Breakdown Voltage
• Min. 8000 V
Insulation Resistance
• Min. 20 MOhm x km
Minimum Bending Radius
• Flexing 10x cable Ø
• Fixed installation 5x cable Ø
Coupling Resistance
• Max. 250 Ohm/km
Radiation Resistance
• Up to 80×106 cJ/kg (up to 80 Mrad)
Cable Structure:
• Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5
• Core insulation of special PVC acc. to UL-Std.1581
• Core identification to DIN VDE 0293 black cores with continuous white numbering
• GN-YE conductor, 3 cores and above in the outer layer
• Cores stranded in layers with optimal selected lay-length
• Separating foil over each layer
• construction with Cu-screening, tinned,approx. 85%
• Minimum coverage 85%
• Outer sheath of special full-polyurethane to DIN VDE 0207-363-10-2/DIN EN 50363-10-12 acc. to UL-Std.1581
• Sheath colour grey (RAL 7001)
• With meter marking
Properties :
• Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2,DIN EN 60332-1-2 / IEC 60332-1(equivalent DIN VDE 0472 part 804test methodB), UL VW-1, CSA FT1
• Suitable for outdoor lying
• Resistant to UV-radiation,oxygen,Ozone,Hydrolyzeandmicrobes
• Low adhesion
• The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers
• Oil resistant to DIN VDE 0473-811-404 /DIN EN 60811-404
Note:
• G = with green-yellow conductor
x = without green-yellow conductor (OZ)
• AWG sizes are approximate equivalent values. The actual cross-section is in mm².
• Analouge type:
JZ-602 RC-PUR
Application:
UL/CSA approved, highly flexible, screened PUR drag-chain cable for laying in dry, damp, wet rooms and outside, with free movement and without
tensile load or forced movements, suitable for frequent lifting and bending stresses in the sector of machine manufacture and tool making. Thanks to
the high level of shielding density, a fault-free transmission of signals or impulses is ensured. The ideal control line, offering protection against
interference, for the above applications. Of interest for those machinery manufacturers, who are export orientated. For applications which go beyond
standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for
our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical
details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
technical specification: | |
awg-no. | 18 |
no.cores x cross-sec. mm² | 5 G 1 |
outer ø app. mm | 8,4 |
cop. weight kg / km | 88,0 |
weight app. kg / km | 136,0 |
helukabel part number. | 12963 |