Belden 1338A Cable 18 AWG 2 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7×26 PVC Jacket 600V Cable
Description:
• 18 AWG stranded (7×26) tinned copper conductors, ground wire, polyolefin insulation, inner and overall Beldfoil® shield (100% coverage), tinned copper drain wire, oil and sunlight resistant PVC jacket.
Ground Wire:
• Ground Wire (Y/N): Y
• Ground Wire AWG: 18
• Ground Wire Stranding: 7×26
• Ground Wire Conductor Material: TC – Tinned Copper
• Ground Wire Insulation Material: PVC – Polyvinyl Chloride
Insulation:
• Material: FRPO – Flame Retardant Polyolefin
Inner Shield:
• Type: Tape
• Inner Shield Material: Aluminum Foil-Polyester Tape
Inner Shield Drain Wire AWG:
• AWG: 18
• Stranding: 7×26
• Conductor Material: TC – Tinned Copper
Outer Shield Drain Wire AWG:
• AWG: 20
• Stranding: 7×28
• Conductor Material: TC – Tinned Copper
Outer Jacket:
• Material: PVC – Polyvinyl Chloride
Mechanical Characteristics (Overall):
• Operating Temperature Range: -30°C To +75°C
• UL Temperature Rating: 75°C
• Max. Recommended Pulling Tension: 112 lbs.
• Min. Bend Radius/Minor Axis: 5.100 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: TC-ER
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 11/01/2007
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Unaveraged Impedance (Ohm): 100.000
• Nom. Inductance (μH/ft): 0.220
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/ft): 45.000
• Nom. Mutual Capacitance (pF/ft): 24.000
• Maximum Capacitance Unbalance (pF/ft): 1.200
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 5.860
• Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 7.500 Ohm/1000 ft
• Max. Operating Voltage – UL: 600 V RMS
• Max. Recommended Current: 5.2 Amps/Conductor
Flame Test:
• UL Flame Test: UL1685 UL Loading
Suitability:
• Suitability – Indoor: Yes
• Suitability – Outdoor: Yes
• Sunlight Resistance: Yes
• Oil Resistance: Yes
Plenum/Non-Plenum:
• Plenum(Y/N): No
technical specification: | |
awg | 18 |
# pairs | 2 |
stranding | 7×26 |
no. of conductors | 5 |
conductor material | tinned copper |
diameter (in.) | – |
outer shield – type | tape |
outer shield – material | aluminum Foil-polyester tape |
overall cable – nominal diameter (in.) | 0.510 |
belden cable part number | 1338A |