Product Details
Technical Data:
• Control cable, special PVC with blue outer sheath for hazardous areas to hazard type -i- (= intrinsically safe)
• For intrinsically safe installation acc. to DIN EN 60079-14 and IEC 60079-14 section 12.2.2 (VDE 0165 part 1)
Temperature Range:
• Flexing -15°C to +80°C
• Fixed installation -40°C to +80°C
Nominal Voltage: U0/U 300/500 V
Test Voltage: 3000 V
Breakdown Voltage: Min. 6000 V
Insulation Resistance: Min. 20 MOhm x km
Mutual Capacitance: Core/core approx. 120 nF/km
Inductance: Approx. 0,68 mH/km
Minimum Bending Radius:
• Flexing 7,5x cable Ø
• Fixed installation 4x cable Ø
Radiation Resistance: Up to 80×106 cJ/kg (up to 80 Mrad)
Cable Structure:
• Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5
• Core insulation of special PVC compound type Z 7225
• Core identification to DIN VDE 0293 black cores with continuous white numbering
• Without GN-YE conductor
• Cores stranded in layers with optimal lay-length
• Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1/DIN EN 50363-4-1
• Sheath colour blue (RAL 5015)
• With meter marking
Properties:
• Extensively oil resistant, oil-/chemical resistance see table Technical Informations
• The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers
Tests:
PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2/IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)
Note:
• For underground laying use NYY with blue outer sheath.
• AWG sizes are approximate equivalent values. The actual cross-section is in mm².
• Instrumentation cable RE-2Y(St)Yv with blue outer sheath see Data and Computer Cables
Application:
For hazardous areas the cables with special marking (blue) (hazard type-i-) used as flexible control and measuring cables to meet the requirements for the installation of electrical apparatus. These installations are not earthed and require a separate power circuit. Those cables are not suitable for underground laying.
awg-no. | no.cores x cross-sec.mm² |
weight app. kg / km |
helukabel part number |
Action |
19 | 2 x 0,75 | 46,0 | 14001 | Request A Quote |
19 | 3 x 0,75 | 54,0 | 14002 | Request A Quote |
19 | 4 x 0,75 | 66,0 | 14003 | Request A Quote |
19 | 5 x 0,75 | 80,0 | 14004 | Request A Quote |
19 | 7 x 0,75 | 110,0 | 14075 | Request A Quote |
19 | 8 x 0,75 | 130,0 | 14005 | Request A Quote |
19 | 12 x 0,75 | 179,0 | 14076 | Request A Quote |
19 | 18 x 0,75 | 257,0 | 14006 | Request A Quote |
19 | 25 x 0,75 | 365,0 | 14007 | Request A Quote |
19 | 30 x 0,75 | 448,0 | 14008 | Request A Quote |
19 | 34 x 0,75 | 510,0 | 14009 | Request A Quote |
19 | 41 x 0,75 | 607,0 | 14010 | Request A Quote |
18 | 2 x 1 | 60,0 | 14011 | Request A Quote |
18 | 3 x 1 | 72,0 | 14012 | Request A Quote |
18 | 4 x 1 | 86,0 | 14013 | Request A Quote |
18 | 5 x 1 | 104,0 | 14014 | Request A Quote |
18 | 7 x 1 | 141,0 | 14015 | Request A Quote |
18 | 12 x 1 | 230,0 | 14016 | Request A Quote |
18 | 18 x 1 | 343,0 | 14017 | Request A Quote |
18 | 25 x 1 | 485,0 | 14018 | Request A Quote |
16 | 2 x 1,5 | 70,0 | 14019 | Request A Quote |
16 | 3 x 1,5 | 90,0 | 14020 | Request A Quote |
16 | 4 x 1,5 | 109,0 | 14021 | Request A Quote |
16 | 5 x 1,5 | 131,0 | 14022 | Request A Quote |
16 | 7 x 1,5 | 184,0 | 14023 | Request A Quote |
16 | 12 x 1,5 | 309,0 | 14024 | Request A Quote |
16 | 18 x 1,5 | 440,0 | 14025 | Request A Quote |
16 | 25 x 1,5 | 620,0 | 14026 | Request A Quote |
16 | 30 x 1,5 | 842,0 | 14027 | Request A Quote |
14 | 3 x 2,5 | 148,0 | 14100 | Request A Quote |
14 | 4 x 2,5 | 178,0 | 14101 | Request A Quote |
14 | 5 x 2,5 | 221,0 | 14102 | Request A Quote |