Specifications:
- Interlocked Armor – Control Cable
- 600 Volt UL Type MC, CT Use, 90°C
- XLP VW-1 XHHW-2 Insulation
- Aluminum Armor
- Copper Conductors
Application:
For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.
Conductors:
Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).
Insulation:
Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.
Grounding Conductor:
Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.
Armor:
Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.
Jacket:
Black sunlight-resistant PVC per UL Standard 1569.
Flame Tests:
UL 1581 70,000 BTU/hr flame test
Color Code:
ICEA Method 1, Table E-2
Connectors:
Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components
Rain Tight: 416MC series – all nickel-plated brass
Size (AWG or kcmil) |
No. of Conductors |
Net Weight |
Overall Diameter (Inches) |
Insulation Thickness (Mils) |
Jacket Thickness (Mils) |
No. of Strands |
Ground Wire Size AWG |
Product Code |
14 Gauge | 2 | 176 | 0.61 | 30 | 50 | 7 | 14 | HW300 01402 |
14 Gauge | 3 | 185 | 0.63 | 30 | 50 | 7 | 14 | HW300 01403 |
14 Gauge | 4 | 210 | 0.67 | 30 | 50 | 7 | 14 | HW300 01404 |
14 Gauge | 5 | 270 | 0.71 | 30 | 50 | 7 | 14 | HW300 01405 |
14 Gauge | 7 | 320 | 0.76 | 30 | 50 | 7 | 14 | HW300 01407 |
14 Gauge | 9 | 388 | 0.84 | 30 | 50 | 7 | 14 | HW300 01409 |
14 Gauge | 10 | 410 | 0.88 | 30 | 50 | 7 | 14 | HW300 01410 |
14 Gauge | 12 | 460 | 0.91 | 30 | 50 | 7 | 14 | HW300 01412 |
14 Gauge | 15 | 550 | 0.95 | 30 | 50 | 7 | 14 | HW300 01415 |
14 Gauge | 19 | 660 | 1.03 | 30 | 50 | 7 | 14 | HW300 01419 |
14 Gauge | 25 | 877 | 1.17 | 30 | 50 | 7 | 14 | HW300 01425 |
14 Gauge | 37 | 1200 | 1.32 | 30 | 50 | 7 | 14 | HW300 01437 |
12 Gauge | 2 | 185 | 0.65 | 30 | 50 | 7 | 12 | HW300 01202 |
12 Gauge | 3 | 215 | 0.69 | 30 | 50 | 7 | 12 | HW300 01203 |
12 Gauge | 4 | 295 | 0.73 | 30 | 50 | 7 | 12 | HW300 01204 |
12 Gauge | 5 | 325 | 0.76 | 30 | 50 | 7 | 12 | HW300 01205 |
12 Gauge | 7 | 400 | 0.83 | 30 | 50 | 7 | 12 | HW300 01207 |
12 Gauge | 9 | 460 | 0.90 | 30 | 50 | 7 | 12 | HW300 01209 |
12 Gauge | 10 | 560 | 0.95 | 30 | 50 | 7 | 12 | HW300 01210 |
12 Gauge | 12 | 615 | 1.00 | 30 | 50 | 7 | 12 | HW300 01212 |
12 Gauge | 15 | 680 | 1.04 | 30 | 50 | 7 | 12 | HW300 01215 |
12 Gauge | 19 | 900 | 1.16 | 30 | 50 | 7 | 12 | HW300 01219 |
12 Gauge | 25 | 1200 | 1.28 | 30 | 50 | 7 | 12 | HW300 01225 |
12 Gauge | 37 | 1450 | 1.46 | 30 | 50 | 7 | 12 | HW300 01237 |
10 Gauge | 2 | 230 | 0.70 | 30 | 50 | 7 | 10 | HW300 01002 |
10 Gauge | 3 | 300 | 0.72 | 30 | 50 | 7 | 10 | HW300 01003 |
10 Gauge | 4 | 345 | 0.79 | 30 | 50 | 7 | 10 | HW300 01004 |
10 Gauge | 5 | 450 | 0.83 | 30 | 50 | 7 | 10 | HW300 01005 |
10 Gauge | 7 | 560 | 0.89 | 30 | 50 | 7 | 10 | HW300 01007 |
10 Gauge | 9 | 640 | 0.99 | 30 | 50 | 7 | 10 | HW300 01009 |
10 Gauge | 12 | 880 | 1.13 | 30 | 50 | 7 | 10 | HW300 01012 |
10 Gauge | 15 | 965 | 1.18 | 30 | 50 | 7 | 10 | HW300 01015 |
10 Gauge | 19 | 1300 | 1.27 | 30 | 50 | 7 | 10 | HW300 01019 |
10 Gauge | 25 | 1500 | 1.42 | 30 | 50 | 7 | 10 | HW300 01025 |
10 Gauge | 37 | 2450 | 1.64 | 30 | 50 | 7 | 10 | HW300 01037 |