Product Details
Conductor: Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Insulation: EP-rubber, IEC 60092-360 (EPR)
Pair / Triple / Quad twisting: color coded cores twisted and wrapped with polyester tape. Pairs/Triples are laid up collectively and screeed by copper backed polyester tape with tinned copper drain wire. Pairs/Triples are identified by numbered tape or by numbers printed directly on the insulated conductors.
Inner covering: No inner covering. (Additional tapes may be applied)
Armour/screen: No armour.
Outer sheath: Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360)
Marking text: E.g. “meter” “year” DRAKA 01 RU(c) 250V S12 2 pair 0.75 mm2 IEC 60092-376 IEC 60332-3-22
Manufacturing unit: DRAKA 01 = Draka Norsk Kabel.
Outer sheath colour: Grey or Blue
Operating temperature: 90°C
Operating Voltage: 150/250(300)V
Standards applied:
• IEC 60092-376 (2003-05) – Design
• IEC 60228 class 2 – Conductor
• IEC 60092-360 – Insulation
• IEC 60092-360 – Sheath
• IEC 60332-1-2 – Flame Retardant
• IEC 60332-3-22 – Flame retardant
• IEC 60754-1,2 – Halogen Free
• IEC 61034-1,2 – Low Smoke
Core Identification Instrumentation cables:
• Pair – Black-Light Blue
• Triple – Black-Light Blue-Brown
• Quad – Black-Light Blue-Brown-Grey
Description:
• RU(C) 250V 2PAIR 0.75mm2 S12
• RU(C) 250V 4PAIR 0.75mm2 S12
• RU(C) 250V 4PAIR 0.75mm2 S12
• RU(C) 250V 8PAIR 0.75mm2 S12
• RU(C) 250V 12PAIR 0.75mm2 S12
• RU(C) 250V 16PAIR 0.75mm2 S12
• RU(C) 250V 19PAIR 0.75mm2 S12
• RU(C) 250V 24PAIR 0.75mm2 S12
• RU(C) 250V 2TRIP 0.75mm2 S12
• RU(C) 250V 4TRIP 0.75mm2 S12
• RU(C) 250V 4TRIP 0.75mm2 S12
• RU(C) 250V 8TRIP 0.75mm2 S12
• RU(C) 250V 16TRIP 0.75mm2 S12
• RU(C) 250V 24TRIP 0.75mm2 S12
• RU(C) 250V 2PAIR 1.5mm2 S12
• RU(C) 250V 4PAIR 1.5mm2 S12
• RU(C) 250V 8PAIR 1.5mm2 S12
• RU(C) 250V 12PAIR 1.5mm2 S12
• RU(C) 250V 12PAIR 1.5mm2 S12
• RU(C) 250V 16PAIR 1.5mm2 S12
• RU(C) 250V 24PAIR 1.5mm2 S12
• RU(C) 250V 2TRIP 1.5mm2 S12
• RU(C) 250V 4TRIP 1.5mm2 S12
• RU(C) 250V 8TRIP 1.5mm2 S12
• RU(C) 250V 12TRIP 1.5mm2 S12
• RU(C) 250V 16TRIP 1.5mm2 S12
• RU(C) 250V 24TRIP 1.5mm2 S12
Sheath Colour:
• GREY
• BLUE
Application: Fixed installation for instrumentation, communication, Control and alarm systems in both EX (Zone 2) and safe areas. Meets the mud resistant requirements in NEK TS 606:2009.
no. of elements |
no. of cores in element |
copper content approx. (kg/km) |
prysmian and draka cable part number |
Action |
2 | 2 | 30 | 895606 | Request A Quote |