Sizes 3-23: Stranded uncoated copper conductor, extruded silicone rubber insulation, glass braid, braid covering.
Standard Identification Code by Method 2, two conductors cabled with fillers, binder or combination binder and
barrier. LSDSGU: cross-linked polyolefin jacket, LSDSGA: cross-linked polyolefin jacket, braided aluminum armor,
paint. Sizes 50-400: Same except silicone rubber-glass tape insulation, no glass braid or braid covering. Letter
Identification Code by Method 5 binder. LSDSGS: same as LSDSGU except double overall shield.
technical specification: | |
conductor size: awg or mcm | 300 |
number of conductors in cable | 2 |
cable type designation | LSDSGU-300 |
area of each conductor(mcm) | 300.000 |
cable** overall diameter max.(inch) | 1.841 |
cable weight per ft. appox.(lbs) | 3.213 |
radius of bend min.(inch) | 11.5 |
cdr id | LTR-5 |
rated voltage max.(rms) | 1000 |
ampacity, each conductor(amps,max) dc or 60 hz (40°c ambient) | 413 |
ampacity, each conductor(amps,max) dc or 60 hz(50°c ambient) | 380 |
ampacity, each conductor(amps,max) 400 hz(40°c ambient) | 347 |
ampacity, each conductor(amps,max) 400 hz(50°c ambient) | 319 |
nsn | 6145-01203-5391 |
seacoast and military part number | MIL-C-24643/15-10UN |